Home
.Product Info
Gastric Analysis
.pH Importance
Doctor Referral
.Links
.Company Info
.Contact Us
.Disclaimer
Doctors Only

One Patient Desktop pH Diagnostic System

As the Examining Physician, you will always hear a wide spectrum of complaints from your Patients.  By adding The Heidelberg pH Diagnostic System to your Method of Testing, you can be assured of having a Comprehensive Overview of the Patients’ First Stage of Digestion.  We believe you will find that the results of your Treatment Protocols will be enhanced from the pH Data, which this Test provides.  There is no guess work involved and the test results are reproducible.

The One-Patient Heidelberg pH Capsule Monitoring System was exclusively designed for New and Growing Private Practices. This pH Testing System can be Inexpensively Expanded to a 2 Patient Testing System at anytime. The One-Patient Testing System is the Ideal pH Diagnostic Tool for Preventive and Alternative Medical Practices.


VIEW A HEIDELBERG pH DIAGNOSTIC TEST SIMULATION!!!                                                                                                                                                                         




One Patient Testing System Includes:
 

VIEW THE NEWEST ADDITION TO THE pH DIAGNOSTIC FAMILY, THE STATE OF THE ART pH CAPSULE LOCATOR

 

1 Heidelberg Interface Module, And Cables
Show Photo

 

1 Dedicated Computer With a Flat Panel Monitor
Show Photo

1 Dual Bay Lithium-Ion Battery Charger
Show Photo

 

1 Ink Jet Printer Show Photo

1 Heidelberg Digital Transceiver Show Photo  

1 ea. Uninterrupted Power Supply
Show Photo

1 Lithium-Ion Dual Prismatic Cell Battery Pack
Show Photo
 

1 Heidelberg One Patient Testing Program CD Package Show Photo

1 Comprehensive Technical Training Manual
Show Photo
 

1 Capsule Calibration Test Fixture Show Photo

2 Lab Glasses for Saline And Rinse.  

3 Medical Grade Test tubes

1 Pint (500 mL) Calibration Solution, pH 1
Show Photo

 

1 pH Capsule Holder for Calibration Purposes Show Photo

1 Pint (500 mL) Calibration Solution, pH 7
Show Photo
 

Includes: Free In House Training Package
(Request Information)

    Recommended Additional Equipment

When the Total Digestive System is in pH Balance, You can virtually always expect higher levels of Conversion and Absorption of ingested foods and Medications.  In addition, you can expect an appreciable enhancement of the Patients’ Immune Systems! This is a very encouraging step for all aspects of Successful Treatment! The Digestive System Supports the Immune System.  Without proper Conversion and Absorption of the Foods, Medications, and Supplements the Immune system cannot function at its optimum level.  The Heidelberg pH Diagnostic System can be used to bring the First Stage of Digestion to its optimum performance level for good Conversion and Absorption.

A HEIDELBERG NORMAL pH PROFILE WITH ALKALI CHALLENGE
SHOWING pH MEASUREMENTS AND TIMING

 

The Clinical Studies on a Thousand Patients, over a Three Year Period, at the Heidelberg University in Germany, verifies that the Normal Re-acidification Time, for a Young Healthy Adult is, between 20 to 22 minutes. 

 The above Graph shows a Fasting Acid level in the Stomach prior to administering an Oral 5cc Saturated Solution of Sodium Bicarbonate. When the Alkali Challenge is administered to the Patient, the Graph line will move upscale to the Neutral or Alkali side.  The Time, required for the Parietal Cells to reacidify the Stomach, will determine the Patient’s condition; Normal, Hypochlorhydric,  Hyperchlorhydric, or Achlorhydric.  As the Age of Patients increase, the Timing for Normal also changesFor all age groups, the Re-acidification Time for Patients’ classified as Normal, falls between 12 to 33 MinutesThis Information is documented in a 1000 Patient Study, which was done by Professor H. G. Noeller at the Heidelberg University, in Heidelberg Germany.

 When Interpreting The Results Of A Heidelberg pH Diagnostic Test, One Of The Most Important Things To Remember Is What The Normal Re-acidification Time Is For A Normal Healthy Adult.

 

A HEIDELBERG Achlorhydria pH PROFILE (Obvious)

 

 Achlorhydria:  Is The Absence of Free Hydrochloric Acid in the Gastric Juices.  Patient's, who have Achlorhydria, may have a form of Pernicious Anemia.  This should show up on a routine Blood Test. Curing the Anemia would generally return Stomach to its Normal Parietal Cell function.  Always check to see if blood work has been done recently.  It pays to be on the “lookout” for Anemia's.  This condition is always pertinent in Patient's that are HIV Positive (Aids).  The Heidelberg pH Diagnostic System can be used to determine the correct amount and type of Medication necessary to promote good Conversion and Absorption in Achlorhydric Patients.  The Heidelberg pH Diagnostic System will not cure HIV Positive Patient's, but it can be used to increase their quality of life.  The Digestive System must work at its optimum level to support the Immune Systems! The absence of HCL reduces the Immune System Viability and promotes the onset of Infectious Diseases.  The Normal presence of HCL in the Stomach actually sterilizes and emulsifies the foods that we eat.

 

A HEIDELBERG HYPOCHLORHYDRIA pH PROFILE (Not Obvious)
               
Alkali Challenge Proves Hypochlorhydria

 

 Hypochlorhydria: Is the diminished secretion of Hydrochloric Acid produced by the Stomach’s Parietal Cells.  It causes Reflex Stomach-Emptying (Dumping).  Patients will lose most of the advantages of the First Phase of Digestion, including Sterilization causing incomplete conversion of Proteins into Amino Acids.  These incomplete Protein conversions can generate Allergens and many other conditions.  This is common in Aging, but it is not limited to Aging, and, as described, is a very common problem with Allergy Patients.

 

HYPERCHLORHYDRIA, With Rapid Reacidification
                Multi-challenged with Alkali Drink

 

Hyperchlorhydria: Is the excess production of Hydrochloric Acid by the Stomach’s Parietal Cells.  In most cases, Hyperchlorhydria Causes Delayed and/or Marked-Delayed Stomach-Emptying-Time.  It is NOT uncommon for a Persons to retain food in their Stomachs, and sometimes, for as long as 24 hours. (Eventually, the pressure of additional meals physically ‘push-the-foods’ out of their Stomachs.) The consumed foods are denied the proper distribution of the necessary Duodenal Juices (Enzymes, Bile, and Physiologic Buffering), required for the next phase of Digestion, which results in poor conversions and absorption, resulting in reduced fortification of their Immune Systems.  Medications, which require a close-to-neutral pH environment (Small Intestines) for absorption, are virtually ‘inoperative’ all of the time, during the Delayed-Stomach-Emptying-Phase.  Hypochlorhydria and Hyperchlorhydria Conditions can be corrected and treated after discovery of the stated condition (s) by special (specific physiologic) Buffering. This condition Does Not require a pH Blocking Medication to correct. Please let us speak with you regarding a simple and inexpensive way of Diagnosis and Treatment (special physiologic buffering regimen, with no medications).  Patient's will feel better, usually by the very next day.

EXCLUSIVITY

Third Party Reimbursement Requires that only Licensed Physicians do this test. Third Party Reimbursement depends totally on Individual States and Individual Insurance Companies, and the Form in which the CPT Coding is Submitted.

The Heidelberg pH Capsule package insert reads: “CAUTION”: Federal law restricts this device to sale only by, or on the order of a Qualified Physician.” (A Patient History Is Required before administering this diagnostic test. Example: Crohn’s Disease, or any history of intestinal blockage (s), adhesions and/or history of bleeding.)

Our Bibliography has 141 Published Clinical Studies.  We are now entering into our thirty-second year with the Heidelberg pH Capsule.

We are always active with Clinical Pharmacology and Pharmacokinetic Research Studies with Major Universities and Major America and European Pharmaceutical Companies.

If you would like additional information by postal mail or e-mail about the Newest Heidelberg Diagnostic System, contact Heidelberg's Customer Service at 1-800-241-7517 or email us at Heidelberg Medical, Inc. A Heidelberg Representative will be happy to speak with you about our New pH Diagnostic System.

Visit our Confidential Physicians Only Area